Model:ReleaseNotes SW.A.05.60.2014.0926 Release Note SW 253B A.05.60.2014.0926 🔎
Original:ReleaseNotes SW.A.05.60.2014.0926 Release Note SW 253B A.05.60.2014.0926 🔎
Descr: Agilent ReleaseNotes_SW.A.05.60.2014.0926 Release Note SW_253B A.05.60.2014.0926.txt
Group:Electronics > Other
Uploaded:28-08-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name ReleaseNotes_SW.A.05.60.2014.0926 Release Note SW_253B A.05.60.2014.0926.txt

== Keysight B150xA Series EasyEXPERT Software A.05.60.2014.0926 Release Notes == == CORRESPONDING FIRMWARE REVISION == This software A.05.60.2014.0926 works with the following firmware. - B1500A/B1505A: A.05.60 or later. - 415xB/C: HOSTC 03.08, SMUC 04.08 or later. == NEW FEATURES == The following features are added in this release. - B1513C support - B1506A configuration support - B1507A configuration support - Keysight re-branding == IMPROVEMENTS == The following improvements are added in this release. - [8958] [Tracer Test] Change to enable marker and read-out during repeat measurement. - [9008] [Tracer Test] Option to limit output polarity according to axis indication polarity - [9022] [Tracer Test] Maximum number of arithmetic operation is to be enhanced. - [9037] [I/V List Sweep] Support of Multi Channel Pulse Sweep - [9042] [Tracer Test] Support of customizing setup templates - [9045] [Test Result Export] Guide to Folder Export for multiple test results - [9046] [Tracer Test] Support of scaling by changing per division - [9055] [Tracer Test] Option to save data of all channels and arithmetic operations - [9063] [Tracer Test] Option for Classic Test conversion with fixed measurement range setting. - [9066] [N1267A Support] Pulse version of Id-Vds Current Collapse is to be added in Application Library. - [9067] [Oscilloscope View] Support of auto scale - [9302] [Database] Need to improve database recovery utility. == FIXED DEFECTS == The following defects are fixed in this release. - [9019] [Quick Test] Unexpected error 111004 occurs for calling readThermometerOfN1265A() built-in function from Function Setup of Classic Test. - [9026] [Tracer Test] Vertical stacking of arithmetic operation panels causes null reference exception for creating or recalling another setup. - [9061] [N1265A Thermometer Support] Timeout error 103003 occurs for enabling thermometer of N1265A at the second of DIO daisy chain. - [9068] [DR13I-010] ASU S/N is not displayed for B1511B on EasyEXPERT Configuration Window. - [9070] [N1265A Thermometer Support] Reading of a thermometer may not be performed during Quick Test. - [9075] [Data Display] Recalling of appended test results may cause remoting exception. - [9090] [N1265A Thermometer Support] Cannot abort thermo-trigger immediately. - [9106] [DR14I-002] Error occured when restoring the EasyEXPERT database folder. - [9157] [Workspace Import/Export] "The directory is not empty." error may be reported at the end of importing/exporting workspace (*.xws) while anti-virus software is running. - [9161] [B1500-60006 Touch Panel Support] Mouse click handling is to be replaced with mouse down handling. == REVISION HISTORY == New Features: - B1511B support for B1500A - B1511B/E5288A support for B1500A - B1514A support for B1



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Agilent ReleaseNotes SW ReleaseNotes SW Desktop A050220121101 - Agilent README.txt README DEE A.05.00.2012.0630 - Agilent nc param - Agilent ReleaseNotes SW ReleaseNotes SW A050320130124 - Agilent ReleaseNotes FW A.05.00.2012.0710.txt ReleaseNotes FW A.05.00.2012.0710 - Agilent Release Note FW A.05.04.2013.0328 ReleaseNotes FW A0504 20130328 - Agilent ReleaseNotes SW ReleaseNotes SW A.05.00.2012.0630 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Sanwa 380-CE

script execution: 0.09 s